Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
The Effect of Interimplant Distance on the Height of the Interimplant Bone Crest When Using Platform-Switched Implants
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 29 , Issue 2
March/April 2009

Pages 141-151


The Effect of Interimplant Distance on the Height of the Interimplant Bone Crest When Using Platform-Switched Implants

Xavier Rodriguez-Ciurana/Xavier Vela-Nebot /Maribel Segala-Torres/Jose Luis Calvo-Guirado/Jordi Cambra/Víctor Mendez-Blanco/Dennis P. Tarnow


PMID: 19408476
DOI: 10.11607/prd.00.0855

A distance of more than 3 mm between two adjacent standard implants has been shown to preserve the interproximal bone peak, resulting in only 0.45 mm of resorption. The purpose of this study was to determine whether use of the platform-switching technique would change the bone resorption patterns between adjacent implants placed less than 3 mm apart. Radiographic studies of bone resorption around 41 pairs of implants placed less than 3 mm apart in 37 patients were carried out. Mean vertical bone resorption was 0.62 mm, and the mean horizontal component was 0.60 mm. The bone peak that extended coronally beyond an imaginary line connecting the two implant-abutment interfaces was measured, and the mean bone height preservation above this interimplant line was 0.24 mm. (Int J Periodontics Restorative Dent 2009;29:141–151.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help